Skip to content
The hangar-door outrigger truss spanning the hangar frontage

Structural FEA of a hangar-door outrigger

CAD development, dead-load response and wind-load assessment

STRUCTURAL DESIGN & FINITE ELEMENT ANALYSIS

Structural FEA of a hangar-door outrigger

01 / PROJECT ARCHITECTURE

A continuous structure across two hangar openings

The numerical history places the result snapshots on the same timeline. Temperature and CO peak at the assumed 25-minute fire cut-off, then decline as the source stops and ventilation continues

Overall assembly length
204.58 m
First opening dimension
80.83 m
Second opening dimension
91.00 m
General arrangement of the outrigger truss across both hangar openings, with overall dimensions

02 / CAD DEVELOPMENT

The column and bracing arrangement evolved together

The February drawings record a change in the tower configuration. The study updates the column sections and replaces the earlier beam-bracing arrangement with X-braced panels, while retaining the truss and rail interfaces within the complete assembly

  • End tower drawing with beam bracing between the columns

    Earlier column arrangement

    The 15 February drawing shows NPB 500 × 200 × 12 columns with NPB 300 × 200 × 9.4 beam bracing

  • End tower drawing with X-braced panels between the columns

    Revised X-braced arrangement

    The 16 February drawing shows NPB 600 × 220 × 9.8 columns and ISA 150 × 150 × 10 angle bracing

These drawings document configuration changes. The supplied analysis does not establish an accepted reanalysis of the later April assembly

03 / ANALYSIS BASIS

Two load cases examined the original support system

The structural study first assessed the dead load and top tracks, then added wind loading. It reviewed the complete frontage before examining individual column assemblies, braces and truss connections. This linked movement across the long spans to the local details carrying those loads

Load cases and what each assessed
STUDY CASEASSESSMENT FOCUS
Case 1 / dead load + top tracksTruss deflection, column movement and connection stress
Case 2 / dead load + windLateral stiffness and the demand on the support strategy
Steel density
7,850 kg/m³
Young’s modulus
200 GPa
Poisson’s ratio
0.29

The report identifies mild structural steel and a yield-strength range of 275–351 MPa. It does not assign one grade or allowable stress to every component

04 / DEAD-LOAD RESPONSE

Different movement across the two hangar spans

Under dead load and top-track loading, the report identifies approximately 83 mm of deformation on the wide-body hangar side and 126 mm on the narrow-body side. The whole-model contour records a peak of 126.736 mm. These results establish the baseline for the component review

  • Isometric displacement contour of the whole outrigger under dead load and top tracks

    Response across the complete frontage

    The original isometric result relates the long trusses, raised opening and three support groups. Colours show displacement magnitude in mm

  • Elevation displacement contour along the truss spans

    Movement along the truss system

    The companion view makes the variation along the two spans visible. Local column results are reviewed separately from the global maximum

05 / COLUMN RESPONSE

Cantilever movement varied between the supports

The end assemblies transfer load through cantilevered upper members into the vertical columns and braces. Their movement differs from the overall truss displacement. Examining each support separately exposed the locations that deserved closer connection-level assessment

  • Displacement contour of the narrow-body hangar end column, peaking at 19.87 mm

    Narrow-body hangar end column

    The report identifies 19.87 mm at the leading end of the cantilever near the paint-hangar side

  • Displacement contour of the wide-body hangar end column, peaking at 8.74 mm

    Wide-body hangar end column

    The corresponding left end assembly shows 8.74 mm, again concentrated towards the cantilever’s leading end

Reported column displacements
ASSEMBLYREPORTED DISPLACEMENTREVIEW LOCATION
Centre column7.776 mmMovement towards the NBH side
NBH corner column19.87 mmLeading end of the cantilever
WBH corner column8.74 mmLeading end of the cantilever

Rounded values follow the report annotations. All three belong to the base-case dead-load and top-track assessment.

06 / LOCAL STRESS REVIEW

Connections became the focus of the design review

The stress plots locate concentrations around member junctions, bolted regions and brace-to-column interfaces. The report specifically calls for redesign of the narrow-body hangar corner column. The close-up views connect that finding to individual joints rather than only the overall frame response

  • Stress contour of the narrow-body hangar column assembly

    NBH column assembly

    The full stress field identifies the critical end support. Its local computed peak is above the material-strength range stated in the report

  • Close-up stress contour of the member-to-column junctions

    Member-to-column junctions

    The enlarged view exposes concentrated response at the connection regions. These details form part of the redesign review

  • Stress contour of the centre support and its bracing

    Centre support and bracing

    The centre assembly also develops local concentrations around its brace and column interfaces as it transfers load from the adjacent spans

  • Stress contour along the truss members and joints

    Truss members and joints

    The truss result extends the review to the load path above the openings, including connection regions and local changes in stiffness

Stress figures are in MPa. Some original detail plots cap the colour scale at 200 MPa while retaining higher computed maxima in their labels. The scale ceiling is not an acceptance limit

07 / WIND-LOAD STUDY

Wind exposed the need to revisit lateral support

The wind study applies a reported speed of 120 km/h (33.3 m/s), with a dynamic pressure of 683.3 Pa. Loads act across the hangar-door areas defined in the report. Adding this lateral demand reveals how strongly the baseline response depends on the stiffness of the column and support arrangement

Wind load by hangar zone
REPORT ZONEIMPACT AREAAPPLIED WINDFORCE
Wide-body hangar1,099.3 m²751.18 kN
Narrow-body hangar1,224.0 m²836.40 kN
  • Isometric displacement contour under wind load, peaking at 2,449.25 mm

    Large computed lateral movement

    The wind case gives a peak displacement of 2,449.25 mm near the tail-gate region, identifying a major stiffness issue in the baseline configuration

  • Plan view of the wind-load displacement relative to the column groups

    Support demand in plan

    The plan view shows the truss movement relative to the column groups. The report recommends revisiting the columns or connecting supports to the main hangar

This is the computed response of the original study model and a basis for redesign. The supplied report does not establish the performance of a completed, revised structure

08 / DETAIL DEVELOPMENT

Rail and base connection details

The drawing package develops the details around the main structural members. Rail-support spacing controls the relationship between the upper truss and the door guides, while base-plate geometry sets out the connection between the steel towers and the civil works

  • Section drawing of the top rails and their supports

    Upper rail coordination

    The section shows the top rails and their supports across the truss width, including the repeated spacing used in the assembly

  • Base plate drawing with its bolt-hole pattern and dimensions

    Base plate and anchor layout

    The foundation detail defines the plate outline and bolt-hole pattern for coordination with the supporting civil structure

09 / FOUNDATION COORDINATION

Three support groups and a continuous rail frontage

The April foundation drawings coordinate the tower groups, anchor locations and lower rails along the frontage. Plan views establish the setting-out geometry, while longitudinal sections relate the deeper support blocks to the continuous rail and ground interface

Foundation plan showing the three tower groups and the bottom rail
Longitudinal foundation section along the rail frontage

Original foundation coordination drawings. Dimensions describe the documented geometry. The provided package does not establish a separate soil or foundation-capacity assessment

Outcome

A clear basis for structural redesign and coordination

The assessment traced the governing behaviour from the long trusses into the cantilevered end supports and local connections. It identified the narrow-body hangar corner column and the lateral support strategy as priorities for further design work Together, the analysis and drawing package provided a documented basis for reviewing the steelwork, rail interfaces and foundation arrangement. The record supports a design-development outcome. Final acceptance of the later geometry is not demonstrated in the supplied analysis

  • Industry Proven Frameworks
  • Get consultancy-level insights

Explore Detailed Case Study

Request a Quote

Tell us about your project

Fields marked * are required.

Choose a file (optional)

Drawings, CAD, images or ZIP (.pdf, .png, .jpg, .jpeg, .dwg, .dxf, .step, .stp, .iges, .igs, .stl, .zip), up to 15 MB.